Call Us : 08045812107
Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway
Modbus TCP to M-Bus Gateway
Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway Modbus TCP to M-Bus Gateway

Modbus TCP to M-Bus Gateway

Product Details:

  • Storage Temperature -30 ~ +80 Celsius (oC)
  • Network Connection Methods Wired
  • Dimension (L*W*H) 102 x 123 x 40 (W x H x D) Millimeter (mm)
  • Weight 450 Grams (g)
  • Material Metal
  • Usage Industrial
  • Color Black
  • Click to View more
X

Modbus TCP to M-Bus Gateway Price And Quantity

  • 10 Piece

Modbus TCP to M-Bus Gateway Product Specifications

  • 102 x 123 x 40 (W x H x D) Millimeter (mm)
  • Metal
  • 450 Grams (g)
  • Industrial
  • Wired
  • -30 ~ +80 Celsius (oC)
  • Black

Modbus TCP to M-Bus Gateway Trade Information

  • Cheque
  • 1000 Piece Per Month
  • 3 Days
  • Device
  • Asia Australia Central America North America South America Eastern Europe Western Europe Middle East Africa
  • All India
  • CE/FCC/ROHS

Product Description

Features

  • Supports M-Bus standard: EN-13757, CJ/T -188
  • Supports Modbus TCP/RTU function code 0x03 and 0x04 to read Meter data
  • Default M-Bus port data format: Data bit 8, Parity Even, Stop bit 1
  • Supports up to 100 M-Bus slaves
  • M-Bus over current protection
  • Short-circuit protection on the M-Bus
  • Update firmware from serial port
  • Watchdog inside

Introduction

M-Bus (Meter-Bus) is a communication interface widely used in various meters, such as electricity meters, watermeters, heat meters, etc. Ease of installation (two-wire system includes power and communication function) androbustness are the most important features. M-Bus has its own physical layer and protocol. Therefore, it is usuallyswitched to other systems, such as Modbus, to facilitate the overall application.

Applications

The M-Bus (MeterïBus) is a bus optimized for the reading of measurement instruments like: energy counters, hot and cold water counters, gas, pressure, sensors and actuators, etc..

Ethernet
Ports 1 x RJ-45, 10/100Base-T(X)
Protocol Modbus TCP
COM Ports
Ports 1 x RS-232, Non-isolated
Baud Rate 300 115200 bps
Parity None, Even, Odd, Mark, Space
Data Bit 5, 6, 7, 8
Stop Bit 1, 2
M-Bus
Ports 1
Baud Rate 300 2400 bps and user-defined baud rate
Data Bit 5, 6, 7, 8
Stop Bit 1, 2
Parity None, Even, Odd, Space, Mark
Isolation 3750 Vrms for photo-couple
Current Protection short-circuit protection
Power
Consumption 1.8 W @ 24 VDC (with 1 slave device), 11.8 W @ 24 VDC (with 100 slave devices)
Mechanical
Dimensions (mm) 102 x 123 x 40 (W x H x D)
Installation Wall mounting
Environment
Operating Temperature -25 +75 ï
Storage Temperature -30 +80 ï
Humidity 10 90% RH, Non-condensing


Enter Buying Requirement Details