BACnet to Modbus RS485 Gateway
Product Details:
- Product Type BACnet IP to Modbus RTU Gateway
- Storage Temperature -30 ~ +80 C Celsius (oC)
- Network Connection Methods Wired
- Dimension (L*W*H) 33 x 120 x 116 Millimeter (mm)
- Weight 450
- Power Supply +10 ~ +30 VDC
- Material metal
- Click to View more
X
BACnet to Modbus RS485 Gateway Price And Quantity
- 10 Piece
BACnet to Modbus RS485 Gateway Product Specifications
- 33 x 120 x 116
- -30 ~ +80 C Celsius (oC)
- +10 ~ +30 VDC
- 33 x 120 x 116 Millimeter (mm)
- metal
- Wired
- 450
- Black
- BACnet IP to Modbus RTU Gateway
BACnet to Modbus RS485 Gateway Trade Information
- Cheque
- 1000 Piece Per Month
- 3 Days
- Device
- Asia Australia Central America North America South America Eastern Europe Western Europe Middle East Africa
- All India
- CE/FCC/ROHS
Product Description
Features
- Read/Write Modbus registers via BACnet objects
- Configurable BACnet/IP Server
- Configurable Modbus RTU Master
- Supports BACnet AI, AO, AV, BI, BO, BV, MSI, MSO, MSV Object Types
- Supports Modbus discrete inputs, coils, input registers and holding registers
- Supports up to 180 DI, 180 DO, 180 AI and 180 AO to transfer to BACnet Objects
- Simple data translation allows you to manipulate data as it passes between protocol
Introduction
GW-2492M is a network gateway allowing BACnet client devices to be accessed Modbus network as a Modbus RTU master. The BACnet/IP protocol is used to relay and exchange information between building devices. GW-2492M contains a large number of BACnet objects (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV) gives you flexibility in mapping Modbus RTU registers to any combination of BACnet objects. Multiple BIBBs (DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B,etc.) are supported. All the data transfer is configurable using a standard Web browser.
Applications
- Building Automation
- Heating, Ventilating, and Air-conditioning Control
- Lighting Control
- Access Control
- Fire Detection Systems
LED Indicators | |
---|---|
Status | Power (1), BACnet/IP Status (1), BACnet/IP Net(1), Modbus RTU TxD/RxD/Link (3) Ethernet LED Ethernet Status (RJ-45) (2) |
Ethernet | |
---|---|
Ports | 1 x RJ-45, 10/100Base-TX |
COM Ports | |
---|---|
Ports | termninal block(D+, D-, TxD, RxD, GND) |
BACnet/IP | |
---|---|
Protocol | Modbus RTU Master (Supports up to 32 stations) |
Objects | AI, AO, AV, BI, BO, BV, MSI, MSO, MSV(Convert modbus 600 DI, 600 DO, 600 AI and 600 AO) |
BIBBs | DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-RD-B |
Power | |
---|---|
Input Range | +10 +30 VDC |
Consumption | 5 W @ 24 VDC |
Mechanical | |
---|---|
Casing | Metal |
Dimensions (mm) | 33 x 120 x 116 |
Installation | DIN-Rail |
Environment | |
---|---|
Operating Temperature | -25 +75 C |
Storage Temperature | -30 +80 C |
Humidity | 10 90% RH, Non-condensing |
Enter Buying Requirement Details